Fast Gas Chromatography with Tandem Mass Spectrometry Analysis of Selected Persistent Organic Pollutants and Organophosphorus and Synthetic Pyrethroid Pesticides in Indian Prawn ( Fenneropenaeus indicus ) in Compliance with the EU-MRLs.

Autor: Sawant D; Ramnarain Ruia College, Department of Chemistry, Mumbai 400 019, India., Kelkar J; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Rasam P; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Datar A; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Hase P; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Handique D; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Bhone A; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Chiplunkar S; Shimadzu Analytical (India) Pvt. Ltd, 1-A/B, Rushabh Chambers, Andheri-East, Mumbai 400 059, India., Hate M; Ramnarain Ruia College, Department of Chemistry, Mumbai 400 019, India.
Jazyk: angličtina
Zdroj: Journal of AOAC International [J AOAC Int] 2017 May 01; Vol. 100 (3), pp. 610-615. Date of Electronic Publication: 2017 Mar 16.
DOI: 10.5740/jaoacint.17-0062
Abstrakt: A fast GC with tandem MS method was developed and validated for multiresidue determination of 95 chemical contaminants (24 synthetic pyrethroids, 17 organochlorines, 17 organophosphorus compounds, 18 polycyclic aromatic hydrocarbons, and 19 polychlorinated biphenyls) in Indian prawns (Fenneropenaeus indicus) as per the European Union maximum residual limit requirements. Chromatographic separation and MS determination were achieved within a short run time of 18 min, without compromising sensitivity and specificity. Our findings revealed a 2.5× reduction in the run time compared with conventional GC methods. Sample preparation involved a QuEChERS-based extraction of 10 g sample with 10 mL acidified acetonitrile (1% acetic acid) and phase separation with 6 g anhydrous magnesium sulfate and 1.5 g sodium acetate. The extract was cleaned in two steps, first by dispersive cleanup with primary secondary amine and then by C18 SPE cartridge. The regression coefficients of linearity (r2) for the concentration range of 5-50 ng/mL were >0.99 for all the compounds. Recoveries at 5 and 10 ng/g levels were within the acceptable range of 70-120%. The repeatability (RSDr) and within-laboratory reproducibility (RSDwR) precisions were ≤20%. The method was successfully applied for analysis of the real world samples for incurred residues.
Databáze: MEDLINE