Accommodation stimulus and response determinations with autorefractors.

Autor: Atchison DA; School of Optometry & Vision Sciences and Institute of Health & Biomedical Innovation, Faculty of Health, Queensland University of Technology, Kelvin Grove, Australia., Varnas SR; Carl Zeiss Vision Australia Holdings Limited, Zeiss Group, Lonsdale, Australia.
Jazyk: angličtina
Zdroj: Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) [Ophthalmic Physiol Opt] 2017 Jan; Vol. 37 (1), pp. 96-104.
DOI: 10.1111/opo.12340
Abstrakt: Purpose: To develop equations for accommodation stimulus and accommodation response with autorefractors when the accommodation stimulus is produced by combinations of object distances and lenses placed in front of eyes, and to give worked examples using these equations.
Methods: Simple ray tracing was used to determine stimulus and response equations, taking into account the reference positions for targets, for refraction, and for autorefractor readings.
Results: Several examples applying equations are provided. Features of these examples include evaluating approximate calculations that have been used previously, demonstrating which equations should be used in different circumstances, how to substitute numbers into equations, how to deal with discrepancies between subjective and objective refraction, and how to deal with astigmatism. Problems associated with measuring accommodation response by placing lenses in front of the eye are discussed.
Conclusions: Accurate equations for accommodation stimulus and accommodation response for a range of accommodation stimuli in different setups have been developed.
(© 2016 The Authors Ophthalmic & Physiological Optics © 2016 The College of Optometrists.)