Impact of synthetic elements on aortic root haemodynamics: computed fluid dynamics of aortic root reconstruction and valve reimplantation.

Autor: Berdajs D; Department of Surgery and Anesthesiology, Cardiovascular Research, University Hospital Lausanne, Lausanne, Switzerland.; Department of Cardiac Surgery, University Hospital Basel, Basel, Switzerland., Mosbahi S; Department of Surgery and Anesthesiology, Cardiovascular Research, University Hospital Lausanne, Lausanne, Switzerland., Strano F; Department of Surgery and Anesthesiology, Cardiovascular Research, University Hospital Lausanne, Lausanne, Switzerland., Forro Z; Swiss Federal Institution of Technology Zürich, Zürich, Switzerland., Burki M; Department of Surgery and Anesthesiology, Cardiovascular Research, University Hospital Lausanne, Lausanne, Switzerland., von Segesser LK; Department of Surgery and Anesthesiology, Cardiovascular Research, University Hospital Lausanne, Lausanne, Switzerland.
Jazyk: angličtina
Zdroj: European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2017 Mar 01; Vol. 51 (3), pp. 432-441.
DOI: 10.1093/ejcts/ezw347
Abstrakt: Objectives: The aim was to evaluate the impact of the aortic valve reimplantation (David) and of the aortic root (AoR) remodelling (Yacoub) on the AoR haemodynamics.
Methods: In an experimental setup where the clinical scenario of Yacoub, ( n =  5, domestic pig) and of David ( n =  5, domestic pig) procedure was performed in each AoR, six high-fidelity (200 Hz) sonomicrometric crystals were implanted. Crystals were positioned at three commissures with their projection at the root base. In post-measurement processing 3D deformation of both AoR was determined and used for computed fluid dynamic modelling in order to evaluate pressure, velocity and shear stress profiles.
Results: In David AoR: high pressure (> 150 mmHg) and low to moderate shear stress (0-30 Pa) were found from the period of isovolemic contraction to the closure of the aortic valve. At mid diastole pressure augmentation (> 120 mmHg) a low shear stress (0-10 Pa) was registered at the leaflets, three commissures, and intervalvular triangles. In Yacoub AoR: high pressure (110-130 mmHg) with moderate low shear stress (0-30 Pa) was only registered at isovolemic contraction.
Conclusions: The results show that haemodynamic conditions following a David procedure have a less favourable pattern as compared to a Yacoub AoR. In David AoR, high pressure and low shear stress are present during 2/3 of the cardiac cycle, whereas in Yacoub root, these conditions are present only for a short period of isovolemic contraction.
(© The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.)
Databáze: MEDLINE