Infarcted rat myocardium: Data from biaxial tensile and uniaxial compressive testing and analysis of collagen fibre orientation.

Autor: Sirry MS; Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Observatory 7925, South Africa; Department of Biomedical Engineering, University of Medical Sciences and Technology, P.O. Box 12810, Khartoum, Sudan., Butler JR; Department of Clinical Sciences, College of Veterinary Medicine, Mississippi State University, Mississippi, MS 39762, USA., Patnaik SS; Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University, Mississippi, MS 39762, USA., Brazile B; Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University, Mississippi, MS 39762, USA., Bertucci R; Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University, Mississippi, MS 39762, USA., Claude A; Department of Clinical Sciences, College of Veterinary Medicine, Mississippi State University, Mississippi, MS 39762, USA., McLaughlin R; Department of Clinical Sciences, College of Veterinary Medicine, Mississippi State University, Mississippi, MS 39762, USA., Davies NH; Cardiovascular Research Unit, Chris Barnard Division of Cardiothoracic Surgery, University of Cape Town, Observatory 7925, South Africa., Liao J; Tissue Bioengineering Laboratory, Department of Agricultural and Biological Engineering, Mississippi State University, Mississippi, MS 39762, USA., Franz T; Division of Biomedical Engineering, Department of Human Biology, University of Cape Town, Observatory 7925, South Africa; Centre for High Performance Computing, Rosebank 7700, South Africa; Bioengineering Science Research Group, Engineering Sciences, Faculty of Engineering and the Environment, University of Southampton, Southampton SO171BJ, UK.
Jazyk: angličtina
Zdroj: Data in brief [Data Brief] 2016 Aug 04; Vol. 8, pp. 1338-43. Date of Electronic Publication: 2016 Aug 04 (Print Publication: 2016).
DOI: 10.1016/j.dib.2016.08.005
Abstrakt: Myocardial infarction was experimentally induced in rat hearts and harvested immediately, 7, 14 and 28 days after the infarction induction. Anterior wall infarct samples underwent biaxial tensile and uniaxial compressive testing. Orientation of collagen fibres was analysed following mechanical testing. In this paper, we present the tensile and compressive stress-strain raw data, the calculated tensile and compressive moduli and the measured angles of collagen orientation. The presented data is associated with the research article titled "Characterisation of the mechanical properties of infarcted myocardium in the rat under biaxial tension and uniaxial compression" (Sirry et al., 2016) [1].
Databáze: MEDLINE