A total analytical system featuring a novel solid-liquid extraction chamber for solid sample flow analysis.

Autor: Galvis-Sánchez AC; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401, Porto, Portugal., Santos JR; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401, Porto, Portugal. jrsantos@porto.ucp.pt., Rangel AO; Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Arquiteto Lobão Vital, Apartado 2511, 4202-401, Porto, Portugal.
Jazyk: angličtina
Zdroj: Analytical and bioanalytical chemistry [Anal Bioanal Chem] 2016 Nov; Vol. 408 (27), pp. 7651-7661. Date of Electronic Publication: 2016 Aug 17.
DOI: 10.1007/s00216-016-9858-4
Abstrakt: In this work, a total flow analysis system based on a novel solid-liquid extraction chamber is presented. This strategy enables all the main experimental procedures for the analysis of a solid sample to be performed automatically: enrichment of the liquid extract, sample treatment, filtration of the liquid extract from the solid sample, directing the extract towards detection, and finally cleansing of the chamber for the following solid sample to be analyzed. The chamber designed to be incorporated in the flow manifold presents two main features: it accommodates stirring bars for enhancing the extraction process, and it presents replaceable solid sample containers (a spare part of the solid-liquid extraction chamber) to easily replace the solid sample and therefore enhance sample analysis throughput. The chamber performance was assessed using two different solid samples, an ion exchanger resin and vegetable samples, focussing on proton and nitrate ion extraction, respectively. The main figures of merit achieved were relative standard deviation (RSD) and relative error values below 7 % for all determinations. The determination rate for vegetable samples was ca. 12 samples h -1 . The proposed strategy may be exploited to perform automatically the analysis of solid samples as it embodies a simple automatic strategy of a very important but time-consuming and laborious analytical operation. Graphical abstract TAS for solid liquid extraction and nitrate potentiometric determination of vegetable samples.
Databáze: MEDLINE