Predicting success of high-flow nasal cannula in pneumonia patients with hypoxemic respiratory failure: The utility of the ROX index.

Autor: Roca O; Critical Care Department, Vall d'Hebron University Hospital, Vall d'Hebron Research Institute, Barcelona, Spain; Ciber Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain. Electronic address: oroca@vhebron.net., Messika J; AP-HP, Hôpital Louis Mourier, Service de Réanimation Médico-Chirurgicale, F-92700 Colombes, France; INSERM, IAME, UMR 1137, F-75018 Paris, France; Univ Paris Diderot, IAME, UMR 1137, Sorbonne Paris Cité, F-75018 Paris, France., Caralt B; Critical Care Department, Vall d'Hebron University Hospital, Vall d'Hebron Research Institute, Barcelona, Spain; Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spains also been shown., García-de-Acilu M; Critical Care Department, Vall d'Hebron University Hospital, Vall d'Hebron Research Institute, Barcelona, Spain., Sztrymf B; AP-HP, Hôpital Antoine Béclère, Service de Réanimation Polyvalente et Surveillance Continue, F-92140 Clamart, France., Ricard JD; AP-HP, Hôpital Louis Mourier, Service de Réanimation Médico-Chirurgicale, F-92700 Colombes, France; INSERM, IAME, UMR 1137, F-75018 Paris, France; Univ Paris Diderot, IAME, UMR 1137, Sorbonne Paris Cité, F-75018 Paris, France., Masclans JR; Ciber Enfermedades Respiratorias (CIBERES), Instituto de Salud Carlos III, Madrid, Spain; Critical Care Department, Mar University Hospital, Mar Research Institute (IMIM), Universitat Pompeu Fabra, Barcelona, Spain.
Jazyk: angličtina
Zdroj: Journal of critical care [J Crit Care] 2016 Oct; Vol. 35, pp. 200-5. Date of Electronic Publication: 2016 May 31.
DOI: 10.1016/j.jcrc.2016.05.022
Abstrakt: Purpose: The purpose of the study is to describe early predictors and to develop a prediction tool that accurately identifies the need for mechanical ventilation (MV) in pneumonia patients with hypoxemic acute respiratory failure (ARF) treated with high-flow nasal cannula (HFNC).
Materials and Methods: This is a 4-year prospective observational 2-center cohort study including patients with severe pneumonia treated with HFNC. High-flow nasal cannula failure was defined as need for MV. ROX index was defined as the ratio of pulse oximetry/fraction of inspired oxygen to respiratory rate.
Results: One hundred fifty-seven patients were included, of whom 44 (28.0%) eventually required MV (HFNC failure). After 12 hours of HFNC treatment, the ROX index demonstrated the best prediction accuracy (area under the receiver operating characteristic curve 0.74 [95% confidence interval, 0.64-0.84]; P<.002). The best cutoff point for the ROX index was estimated to be 4.88. In the Cox proportional hazards model, a ROX index greater than or equal to 4.88 measured after 12 hours of HFNC was significantly associated with a lower risk for MV (hazard ratio, 0.273 [95% confidence interval, 0.121-0.618]; P=.002), even after adjusting for potential confounding.
Conclusions: In patients with ARF and pneumonia, the ROX index can identify patients at low risk for HFNC failure in whom therapy can be continued after 12 hours.
(Copyright © 2016 Elsevier Inc. All rights reserved.)
Databáze: MEDLINE