Sonographic detection of tracheal or esophageal intubation: A cadaver study.

Autor: Tejesh CA; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India., Manjunath AC; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India., Shivakumar S; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India., Vinayak PS; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India., Yatish B; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India., Geetha CR; Department of Anaesthesiology, MS Ramaiah Medical College, Bengaluru, Karnataka, India.
Jazyk: angličtina
Zdroj: Saudi journal of anaesthesia [Saudi J Anaesth] 2016 Jul-Sep; Vol. 10 (3), pp. 314-6.
DOI: 10.4103/1658-354X.174922
Abstrakt: Background: The correct position of the endotracheal tube is confirmed by various modalities, most of which are not entirely reliable. Ultrasound is now increasingly available to anesthesiologists in the operating theater and is an attractive alternative. To investigate the usefulness of sonography in identifying the correct tracheal tube position in human cadavers.
Materials and Methods: Endotracheal tubes placed randomly into trachea or esophagus was identified with a linear ultrasound probe placed transversely just above the suprasternal notch by a single anesthesiologist.
Results: Of the 100 intubations performed at random, 99 were correctly identified to give a sensitivity of 100% and a specificity of 97.9%.
Conclusion: Sonography is a useful technique to identify correct position of the tracheal tube.
Databáze: MEDLINE