Survey of Intraoperative Bacterial Contamination in Dogs Undergoing Elective Orthopedic Surgery.

Autor: Andrade N; Department of Small Animal Medicine and Surgery., Schmiedt CW; Department of Small Animal Medicine and Surgery., Cornell K; Department of Small Animal Medicine and Surgery., Radlinsky MG; Department of Small Animal Medicine and Surgery., Heidingsfelder L; Department of Small Animal Medicine and Surgery., Clarke K; Department of Small Animal Medicine and Surgery., Hurley DJ; Department of Population Health, College of Veterinary Medicine, University of Georgia, Athens, Georgia., Hinson WD; Department of Small Animal Medicine and Surgery.
Jazyk: angličtina
Zdroj: Veterinary surgery : VS [Vet Surg] 2016 Feb; Vol. 45 (2), pp. 214-22. Date of Electronic Publication: 2016 Jan 12.
DOI: 10.1111/vsu.12438
Abstrakt: Objective: To investigate the frequency, source, and risk factors of intraoperative (IO) surgeon and patient bacterial contamination during clean orthopedic surgeries, and to investigate the relationship between IO contamination and surgical site infection (SSI) in dogs.
Study Design: Prospective clinical study.
Sample Population: Client-owned dogs undergoing stifle surgery (n = 100).
Methods: IO cultures were taken in each case from surgical foot wrap, peri-incisional skin, surgical gloves, and the surgical team's hands. The environment (operating room [OR] lights, computers, scrub sink faucet, anesthesia gurney, and radiology table) was sampled every 5 months. Bacteria were identified and the contamination of each case was categorized. All gloves from the surgical team were collected and tested for perforations using a water infusion test. Cases were followed for at least 8 weeks to determine the presence or absence of SSI. Perioperative variables were evaluated for association with IO contamination and SSI.
Results: Bacterial isolates were yielded from 81% of procedures from 1 or more sources; 58% had positive hand cultures, 46% had positive glove cultures, 23% had positive patient skin cultures, and 12% had positive foot wrap cultures. Staphylococcus spp. was the most commonly recovered bacteria. There was no apparent association between IO contamination and SSI. The highest level of environmental contamination was associated with the scrub sink faucet, followed by the radiology table, anesthesia gurney, and OR computers. The IO glove perforation rate was 18%.
Conclusion: Clean orthopedic procedures commonly had clinically insignificant bacterial contamination. In our study, bacteria responsible for SSI did not appear to colonize the patient in the OR.
(© Copyright 2016 by The American College of Veterinary Surgeons.)
Databáze: MEDLINE