Pre-operative templating for trauma hemiarthroplasty (Thompson's).
Autor: | Green RN; Trauma and Orthopaedics, Northern Deanery, Newcastle upon Tyne, Tyne and Wear NE21HJ, UK., Rushton PR; Trauma and Orthopaedics, Northern Deanery, Newcastle upon Tyne, Tyne and Wear NE21HJ, UK., Kramer D; North Tyneside General Hospital, UK., Inman D; North Tyneside General Hospital, UK., Partington PF; Wansbeck General Hospital, UK. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of orthopaedics [J Orthop] 2015 May 29; Vol. 12 (4), pp. 248-52. Date of Electronic Publication: 2015 May 29 (Print Publication: 2015). |
DOI: | 10.1016/j.jor.2015.05.005 |
Abstrakt: | Introduction: Surgical complications may be avoided by preoperative templating in trauma hemiarthroplasty. Materials and Methods: Digital templates for the Stryker™ range of Thompson's prostheses were created and fifty trauma patients that had undergone cemented hemiarthroplasty were retrospectively templated by 2 blinded surgeons. Results: Templating for prosthesis size was highly accurate with excellent Inter and intra-observer reproducibility. Sensitivity for identifying femoral canals too narrow for a Thompsons was 100%. Conclusions: Templating is a valuable tool and should be standard practice in trauma. We have demonstrated that it is possible to generate custom templates to allow accurate templating. |
Databáze: | MEDLINE |