Sealing ability of three root-end filling materials prepared using an erbium: Yttrium aluminium garnet laser and endosonic tip evaluated by confocal laser scanning microscopy.
Autor: | Nanjappa AS; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India., Ponnappa KC; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India., Nanjamma KK; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India., Ponappa MC; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India., Girish S; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India., Nitin A; Department of Conservative Dentistry and Endodontics, Coorg Institute of Dental Science, Virajpet, Karnataka, India. |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of conservative dentistry : JCD [J Conserv Dent] 2015 Jul-Aug; Vol. 18 (4), pp. 327-30. |
DOI: | 10.4103/0972-0707.159746 |
Abstrakt: | Aims: (1) To compare the sealing ability of mineral trioxide aggregate (MTA), Biodentine, and Chitra-calcium phosphate cement (CPC) when used as root-end filling, evaluated under confocal laser scanning microscope using Rhodamine B dye. (2) To evaluate effect of ultrasonic retroprep tip and an erbium:yttrium aluminium garnet (Er:YAG) laser on the integrity of three different root-end filling materials. Materials and Methods: The root canals of 80 extracted teeth were instrumented and obturated with gutta-percha. The apical 3 mm of each tooth was resected and 3 mm root-end preparation was made using ultrasonic tip (n = 30) and Er:YAG laser (n = 30). MTA, Biodentine, and Chitra-CPC were used to restore 10 teeth each. The samples were coated with varnish and after drying, they were immersed in Rhodamine B dye for 24 h. The teeth were then rinsed, sectioned longitudinally, and observed under confocal laser scanning microscope. Statistical Analysis Used: Data were analyzed using one-way analysis of variance (ANOVA) and a post-hoc Tukey's test at P < 0.05 (R software version 3.1.0). Results: Comparison of microleakage showed maximum peak value of 0.45 mm for Biodentine, 0.85 mm for MTA, and 1.05 mm for Chitra-CPC. The amount of dye penetration was found to be lesser in root ends prepared using Er:YAG laser when compared with ultrasonics, the difference was found to be statistically significant (P < 0.05). Conclusions: Root-end cavities prepared with Er:YAG laser and restored with Biodentine showed superior sealing ability compared to those prepared with ultrasonics. |
Databáze: | MEDLINE |
Externí odkaz: |