Measurement of the percentage of root filling in oval-shaped canals obturated with Thermafil Obturators and Beefill 2in1: In vitro study.

Autor: Faus-Llácer V; DDS, Professor. Department of Dental Pathology, Conservative Dentistry and Endodontic, Department of Stomatology, Faculty of Medicine and Odontology, University of Valencia., Collado-Castellanos N; Postgraduate Degree. Department of Dental Pathology, Conservative Dentistry and Endodontic, Department of Stomatology, Faculty of Medicine and Odontology, University of Valencia., Alegre-Domingo T; Associate Professor. Department of Dental Pathology, Conservative Dentistry and Endodontic, Department of Stomatology, Valencia University Medical and Dental School., Dolz-Solsona M; Postgraduate Degree. Department of Dental Pathology, Conservative Dentistry and Endodontic, Department of Stomatology, Faculty of Medicine and Odontology, University of Valencia., Faus-Matoses V; Associate Professor. Department of Dental Pathology, Conservative Dentistry and Endodontic, Department of Stomatology, Valencia University Medical and Dental School.
Jazyk: angličtina
Zdroj: Journal of clinical and experimental dentistry [J Clin Exp Dent] 2015 Apr 01; Vol. 7 (2), pp. e299-303. Date of Electronic Publication: 2015 Apr 01 (Print Publication: 2015).
DOI: 10.4317/jced.52177
Abstrakt: Background: The aim of the study was to measure the percentage of root canal fillings in long oval canals obturated with thermoplasticized gutta-percha techniques, Beefill 2in1® and Thermafil Obturators®.
Material and Methods: Fifty four mandibular incisors were selected after bucco-lingual and mesio-distal radiographs showed at 5 mm from apex an internal long:short diameter ≥2. Teeth were instrumented with Protaper Universal and divided in two groups of 27. Group 1 was obturated with Thermafil Obturators® and group 2 with Beefill 2in1®. Two horizontal sections were cut at 5 and 7 mm from the apex and photographed in a stereo-microscope. The total area of the canal and filled canal in cross-sections were measured with AutoCad and the percentages of gutta-percha-sealer and voids in the canal were obtained.
Results: Both systems achieved high percentage of filled canal, Thermafil 96.8% and Beefill 2in1 98.9%. The percentages of voids in both groups were very low. No significant differences were found between the two groups . The percentage obtained at 5 and 7 mm from the apex in both groups showed no significant difference.
Conclusions: The percentages of filled canal (gutta-percha-sealer) were high and these two thermoplasticized techniques are suitable for long oval canals obturation. Key words:Long oval canal, oval canal, thermoplasticized obturation.
Databáze: MEDLINE