Optimization of a free water elimination two-compartment model for diffusion tensor imaging.
Autor: | Hoy AR; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI 53705, USA; Lieutenant, Medical Service Corps, United States Navy, USA; Waisman Laboratory for Brain Imaging and Behavior, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, WI 53705, USA. Electronic address: ahoy@wisc.edu., Koay CG; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI 53705, USA., Kecskemeti SR; Waisman Laboratory for Brain Imaging and Behavior, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, WI 53705, USA., Alexander AL; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, 1111 Highland Avenue, Madison, WI 53705, USA; Waisman Laboratory for Brain Imaging and Behavior, University of Wisconsin-Madison, 1500 Highland Avenue, Madison, WI 53705, USA; Department of Psychiatry, University of Wisconsin-Madison, 6001 Research Park Blvd, Madison, WI 53719, USA. |
---|---|
Jazyk: | angličtina |
Zdroj: | NeuroImage [Neuroimage] 2014 Dec; Vol. 103, pp. 323-333. Date of Electronic Publication: 2014 Sep 28. |
DOI: | 10.1016/j.neuroimage.2014.09.053 |
Abstrakt: | Diffusion tensor imaging is used to measure the diffusion of water in tissue. The diffusion properties carry information about the relative organization and structure of the underlying tissue. In the case of a single voxel containing both tissue and a fast diffusing component such as free water, a single diffusion tensor is no longer appropriate. A two-tensor free water elimination model has previously been proposed to correct for the case of volume mixing. Here, this model was implemented in a straightforward but novel manner without the use of spatial constraints. The optimal acquisition parameters were investigated through Monte Carlo simulations and human brain imaging studies. At a signal-to-noise ratio of 40 with 64 diffusion-weighted encoding images, the most accurate estimates of fast diffusion signal were obtained with two diffusion-weighted shells (b-value in s/mm(2)×number of directions) of 500×32 and 1500×32. The potential bias in fractional anisotropy induced by this two-compartment model was more than an order of magnitude less than the error of using the single diffusion tensor model in the presence of partial volume effects with free water. This strategy may be useful for characterizing the diffusion of tissues adjacent to cerebral spinal fluid (CSF), tissues affected by edema, and removing artifacts from blurring and ghosting of the CSF signal. (Published by Elsevier Inc.) |
Databáze: | MEDLINE |
Externí odkaz: |