Fuel burnup calculation of Ghana MNSR using ORIGEN2 and REBUS3 codes.

Autor: Abrefah RG; National Nuclear Research Institute, Ghana Atomic energy Commission, P.O. Box LG80, Accra, Ghana. adibola2001@yahoo.com, Nyarko BJ, Fletcher JJ, Akaho EH
Jazyk: angličtina
Zdroj: Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2013 Oct; Vol. 80, pp. 12-6. Date of Electronic Publication: 2013 Jun 03.
DOI: 10.1016/j.apradiso.2013.05.007
Abstrakt: Ghana Research Reactor-1 core is to be converted from HEU fuel to LEU fuel in the near future and managing the spent nuclear fuel is very important. A fuel depletion analysis of the GHARR-1 core was performed using ORIGEN2 and REBUS3 codes to estimate the isotopic inventory at end-of-cycle in order to help in the design of an appropriate spent fuel cask. The results obtained for both codes were consistent for U-235 burnup weight percent and Pu-239 build up as a result of burnup.
(Copyright © 2013 Elsevier Ltd. All rights reserved.)
Databáze: MEDLINE