Doses in sensitive organs during prostate treatment with a 60Co unit.
Autor: | Vega-Carrillo HR; Unidad Académica de Estudios Nucleares, Universidad Autonoma de Zacatecas, C. Cipres 10, Fracc. La Peñuela, Zacatecas 98068, Zac., Mexico. Electronic address: fermineutron@yahoo.com., Navarro Becerra JA, Pérez Arrieta ML, Pérez-Landeros LH |
---|---|
Jazyk: | angličtina |
Zdroj: | Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine [Appl Radiat Isot] 2014 Jan; Vol. 83 Pt C, pp. 227-9. Date of Electronic Publication: 2013 May 09. |
DOI: | 10.1016/j.apradiso.2013.05.003 |
Abstrakt: | Using thermoluminiscent dosimeters the absorbed dose in the bladder, rectum and thyroid have been evaluated when 200 cGy was applied to the prostate. The treatment was applied with a (60)Co unit. A water phantom was built and thermoluminiscent dosimeters were located in the position where the prostate, bladder, rectum and thyroid are located. The therapeutic beam was applied in 4 irradiations at 0, 90, 180 and 270° with the prostate at the isocenter. The TLDs readouts were used to evaluate the absorbed dose in each organ. The absorbed doses were used to estimate the effective doses and the probability of developing secondary malignacies in thyroid, rectum and bladder. (Copyright © 2013 Elsevier Ltd. All rights reserved.) |
Databáze: | MEDLINE |
Externí odkaz: |