Automated extraction of ejection fraction for quality measurement using regular expressions in Unstructured Information Management Architecture (UIMA) for heart failure.

Autor: Garvin JH; IDEAS Center, SLC VA Healthcare System, Salt Lake City, Utah 84148, USA. jennifer.garvin@va.gov, DuVall SL, South BR, Bray BE, Bolton D, Heavirland J, Pickard S, Heidenreich P, Shen S, Weir C, Samore M, Goldstein MK
Jazyk: angličtina
Zdroj: Journal of the American Medical Informatics Association : JAMIA [J Am Med Inform Assoc] 2012 Sep-Oct; Vol. 19 (5), pp. 859-66. Date of Electronic Publication: 2012 Mar 21.
DOI: 10.1136/amiajnl-2011-000535
Abstrakt: Objectives: Left ventricular ejection fraction (EF) is a key component of heart failure quality measures used within the Department of Veteran Affairs (VA). Our goals were to build a natural language processing system to extract the EF from free-text echocardiogram reports to automate measurement reporting and to validate the accuracy of the system using a comparison reference standard developed through human review. This project was a Translational Use Case Project within the VA Consortium for Healthcare Informatics.
Materials and Methods: We created a set of regular expressions and rules to capture the EF using a random sample of 765 echocardiograms from seven VA medical centers. The documents were randomly assigned to two sets: a set of 275 used for training and a second set of 490 used for testing and validation. To establish the reference standard, two independent reviewers annotated all documents in both sets; a third reviewer adjudicated disagreements.
Results: System test results for document-level classification of EF of <40% had a sensitivity (recall) of 98.41%, a specificity of 100%, a positive predictive value (precision) of 100%, and an F measure of 99.2%. System test results at the concept level had a sensitivity of 88.9% (95% CI 87.7% to 90.0%), a positive predictive value of 95% (95% CI 94.2% to 95.9%), and an F measure of 91.9% (95% CI 91.2% to 92.7%).
Discussion: An EF value of <40% can be accurately identified in VA echocardiogram reports.
Conclusions: An automated information extraction system can be used to accurately extract EF for quality measurement.