Calcium phosphate cement in orbital reconstructions.

Autor: Ciprandi MT; Department of Oral and Maxillofacial Surgery, School of Dentistry, Universidade Luterana do Brasil, Canoas-RS, Brazil., Primo BT, Gassen HT, Closs LQ, Hernandez PA, Silva AN Jr
Jazyk: angličtina
Zdroj: The Journal of craniofacial surgery [J Craniofac Surg] 2012 Jan; Vol. 23 (1), pp. 145-8.
DOI: 10.1097/SCS.0b013e3182413d31
Abstrakt: Treatment of facial trauma sequelae is a complex and challenging process. There is still controversy over suitable materials for orbital wall reconstruction. This study evaluated calcium phosphate cement (CPC) implants manufactured by rapid prototyping in the repair of orbital wall defects secondary to trauma. Computed tomographic scans of 5 patients were used for surgery planning and production of CPC implants. Implants were used to restore orbital wall anatomy, ocular alignment, and facial contour. Benefits resulting from the use of implants, such as a reduced operating time, patient response to biomaterial implantation, biomaterial integrity and stability, and patient satisfaction with treatment, were analyzed qualitatively. Our results suggest that CPC is an effective and safe material for orbital reconstruction because of its biocompatibility and easy production and placement.
Databáze: MEDLINE