Comparison between F-Fluorodeoxyglucose Positron Emission Tomography and Sentinel Lymph Node Biopsy for Regional Lymph Nodal Staging in Patients with Melanoma: A Review of the Literature.

Autor: Mirk P; Department of Bioimaging and Radiological Sciences, Institute of Radiology, Catholic University of the Sacred Heart, 00168 Rome, Italy., Treglia G, Salsano M, Basile P, Giordano A, Bonomo L
Jazyk: angličtina
Zdroj: Radiology research and practice [Radiol Res Pract] 2011; Vol. 2011, pp. 912504. Date of Electronic Publication: 2011 Dec 22.
DOI: 10.1155/2011/912504
Abstrakt: Aim. to compare (18)F-Fluorodeoxyglucose positron emission tomography (FDG-PET) to sentinel lymph node biopsy (SLNB) for regional lymph nodal staging in patients with melanoma. Methods. We performed a literature review discussing original articles which compared FDG-PET to SLNB for regional lymph nodal staging in patients with melanoma. Results and Conclusions. There is consensus in the literature that FDG-PET cannot replace SLNB for regional lymph nodal staging in patients with melanoma.