Patient environment microbial burden reduction: a pilot study comparison of 2 terminal cleaning methods.
Autor: | Schmidt MG; Department of Microbiology and Immunology, Medical University of South Carolina, Charleston, SC, USA., Anderson T, Attaway HH 3rd, Fairey S, Kennedy C, Salgado CD |
---|---|
Jazyk: | angličtina |
Zdroj: | American journal of infection control [Am J Infect Control] 2012 Aug; Vol. 40 (6), pp. 559-61. Date of Electronic Publication: 2011 Oct 05. |
DOI: | 10.1016/j.ajic.2011.07.013 |
Abstrakt: | Effective cleaning of the patient environment has been advocated to reduce the risk for nosocomial infection. This pilot study compared 2 terminal cleaning methods, a traditional method in which a disinfectant was applied with a wetted cloth and an alternative method in which the disinfectant was applied using the PureMist system (PureCart Systems, Green Bay, WI). There was no difference in effectiveness, with a mean relative reduction of microbial burden of 84% for the traditional method versus 88% for the PureMist method. (Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.) |