[Macromolecular spin pH-probes on the basis of human serum albumin].

Autor: Khramtsov VV, Vaĭner LM, Rar VA, Berezina TA, Martin VV, Volodarskiĭ LB
Jazyk: ruština
Zdroj: Biokhimiia (Moscow, Russia) [Biokhimiia] 1990 Jun; Vol. 55 (6), pp. 1014-7.
Abstrakt: Human serum albumin has been chemically modified by two different spin pH-sensitive labels of the imidazoline series containing in their structure alkylating and carboxyl groups, respectively. The ESR spectra of spin-labeled proteins are sensitive to pH of the medium. The pK values of spin-labeled proteins measured by the ESR method are: pKI = 3.2 +/- 0.1; pKII = 4.75 +/- 0.1. The resulting macromolecular spin pH probes may be used for measuring the local values of pH by the ESR technique within the pH range of 1.8-6.2.