MP-HA: multicycles protocol for hospital automation over multicast addressing.

Autor: de M Valentim RA; Federal Center of Technological Education of Rio Grande do Norte (CEFET-RN), Brazil. valentim@cefetrn.br, Morais AH, Brandao GB, Guerreiro AM, Xavier MA, Junior HB, Bezerra HU, Florentino GH, Paz de Araujo CA
Jazyk: angličtina
Zdroj: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference [Annu Int Conf IEEE Eng Med Biol Soc] 2008; Vol. 2008, pp. 1498-501.
DOI: 10.1109/IEMBS.2008.4649452
Abstrakt: This paper presents a Multicycles Protocol for Hospital Automation (MP-HA) that works over multicast addressing and uses a Master-Slave architecture. The protocol creates a segmented logical network based on multicast addressing associated to hospital beds. The objective of MP-HA is to ensure the determinism on network through medium access control mechanism increasing the transmission throughput. Thus, it creates a periodical environment making use of parallel cycles which is called multicycles.