Quantitative electron holographic tomography for the 3D characterisation of semiconductor device structures.

Autor: Twitchett-Harrison AC; Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge, CB2 3QZ, UK. a.harrison@imperial.ac.uk, Yates TJ, Dunin-Borkowski RE, Midgley PA
Jazyk: angličtina
Zdroj: Ultramicroscopy [Ultramicroscopy] 2008 Oct; Vol. 108 (11), pp. 1401-7. Date of Electronic Publication: 2008 Jun 25.
DOI: 10.1016/j.ultramic.2008.05.014
Abstrakt: Electron tomography and electron holography experiments have been combined to investigate the 3D electrostatic potential distribution in semiconductor devices. The experimental procedure for the acquisition and data reconstruction of holographic tilt series of silicon p-n junction specimens is described. A quantitative analysis of the experimental results from specimens of two different thicknesses is presented, revealing the 3D electrostatic potential variations arising from the presence of surfaces and damage generated by focused ion beam (FIB) sample preparation. Close to bulk-like properties are measured in the centre of the tomographic reconstruction of the specimen, revealing higher electrically active dopant concentrations compared to the measurements obtained at the specimen surfaces. A comparison of the experimental results from the different thickness specimens has revealed a 'critical' thickness for this specimen preparation method of 350nm that is required for this device structure to retain 'bulk'-like properties in the centre of the membrane.
Databáze: MEDLINE