Three-dimensional analysis of pulmonary venous ostial and antral anatomy: implications for balloon catheter-based pulmonary vein isolation.

Autor: Ahmed J; Cardiac Arrhythmia Service, Massachusetts General Hospital-Harvard Medical School, Boston 02114, USA., Sohal S, Malchano ZJ, Holmvang G, Ruskin JN, Reddy VY
Jazyk: angličtina
Zdroj: Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2006 Mar; Vol. 17 (3), pp. 251-5.
DOI: 10.1111/j.1540-8167.2005.00339.x
Abstrakt: Background: Balloon ablation catheters using various energy sources are being developed to perform pulmonary vein (PV) isolation to treat atrial fibrillation. Prior evaluations of 2D CT/MR images are limited by the frequent elliptical shape of the PV ostia, the nonorthogonal orientation of the PVs to the left atrial (LA) chamber, and difficulty in appreciating through-slice curvature. To provide anatomical data relevant to balloon catheter ablation, 3D surface reconstructions of LA-PVs were generated and analyzed to define ostial architecture and size.
Methods and Results: Using MRI datasets obtained from 101 paroxysmal AF patients, the LA-PVs were segmented to generate 3D LA-PV surface reconstructions. Using both external and endoluminal projections, the PV ostial and antral regions were identified and evaluated. In the left PVs, a common left-sided ostium was identified in 94 patients, with an ostial circumference of 95 +/- 15 mm. Branching of the left PVs occurred 0-5 mm away from the common left ostium in 43 patients (43%), 5-15 mm away from the common os in 37 patients (37%), and >15 mm away from the common os in 14 patients (14%). In patients with either distinct left PV ostia, or common os <15 mm (87 patients), the individual LSPV/LIPV ostial circumferences were 67 +/- 12 mm and 58 +/- 9 mm, respectively. Mean left antral circumference was 114 +/- 17 mm. In the right PVs, the ostial circumferences of the RSPV/RIPV were 68 +/- 11 mm and 66 +/- 11 mm, respectively. Mean right antral circumference was 107 +/- 19 mm. Assuming ideal deformation of the LA chamber anatomy, the minimal diameters of a balloon ablation catheter required to isolate 95% of the RSPV, RIPV, LSPV, LIPV, LCPV, left antrum, and right antrum are 29 mm, 28 mm, 29 mm, 24 mm, 40 mm, 46 mm, and 47 mm, respectively.
Conclusion: Analysis of 3D surface reconstructions of LA-PV anatomy reveals that balloon catheter-based ablation of the PVs is likely feasible in most patients, but balloon ablation of the common PV antra would be problematic.
Databáze: MEDLINE
Nepřihlášeným uživatelům se plný text nezobrazuje