Internal carotid blood flow and cerebral hemispheric perfusion in patients with subarachnoid haemorrhage: a study of the quantix/NDtrade mark system and CT perfusion technology.
Autor: | Johnson RD; Department of Human Anatomy & Genetics, Haywards Heath, West Susex, University of Oxford, UK., Liebenberg WA, Jones R, Critchley G |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of neuroradiology = Journal de neuroradiologie [J Neuroradiol] 2005 Dec; Vol. 32 (5), pp. 342-4. |
DOI: | 10.1016/s0150-9861(05)83166-9 |
Abstrakt: | Objective: To assess whether carotid blood flow measurements predict abnormalities in cerebral hemispheric perfusion. Design: The Quantix/NDTM system was used to measure carotid artery blood flow in nine patients with subarachnoid haemorrhage who underwent CT perfusion scanning. Results: No significant correlation was found between internal carotid artery blood flow and ipsilateral cerebral hemispheric perfusion (013, p>0.05) but there was a statistically significant correlation between total internal carotid and global cerebral perfusion (0.63, p<0.05). Conclusions: This is the first report comparing the Quantix/NDTM system with CT perfusion. Our data do not show a statistically significant correlation between extracranial blood flow and cerebral hemispheric perfusion. This is in contrast to two previous studies where Quantix/NDTM measurements were compared with measurements of cerebral perfusion using the Xenon clearance technique. |
Databáze: | MEDLINE |
Externí odkaz: |