[Coronary pressure measurement for functional evaluation and treatment of intermediate angiographic stenosis].

Autor: Pirel M; Service d'hémodynamique et de cardiologie interventionnelle, hôpital cardiovasculaire Louis Pradel, Lyon., Rioufol G, André-Fouët X, Staat P, Bonnefoy-Cudraz E, Rossi R, De Gevigney G, Finet G
Jazyk: francouzština
Zdroj: Archives des maladies du coeur et des vaisseaux [Arch Mal Coeur Vaiss] 2004 Oct; Vol. 97 (10), pp. 957-64.
Abstrakt: Accurate understanding of the physiopathology of a coronary stenosis is a major objective in management during diagnostic coronary angiography. Measurement of fractional flow reserve (FFR) by coronary pressure measurement is a reliable method for evaluating the functional consequences of a lesion of the myocardium. This retrospective monocentric study of 114 patients showed that routine coronary pressure measurement for assessing the functional consequences of intermediate (30 to 70% stenosis) lesions or those of ambiguous topography: was necessary in 4% of diagnostic coronary angiographies enabling an immediate management decision. Using this method, 34% of complementary investigations were not performed (stress test, myocardial scintigraphy, dobutamine stress echocardiography). Seventeen per cent of unnecessary angioplasties were also avoided so that acute coronary event were also avoided when lesions with a FFR >0.75 were not treated by angioplasty. A 10-14% reduction in cost was achieved compared with a strategy of systematic angioplasty in respectively mono- or multivessel disease patients and 39% compared with performing ambulatory myocardial scintigraphy in patients with multivessel disease.
Databáze: MEDLINE