Stability and effectiveness against bacterial adhesion of poly(ethylene oxide) coatings in biological fluids.
Autor: | Roosjen A; Department of Biomedical Engineering, University of Groningen, Antonius Deusinglaan 1, 9713 AV Groningen, The Netherlands., de Vries J, van der Mei HC, Norde W, Busscher HJ |
---|---|
Jazyk: | angličtina |
Zdroj: | Journal of biomedical materials research. Part B, Applied biomaterials [J Biomed Mater Res B Appl Biomater] 2005 May; Vol. 73 (2), pp. 347-54. |
DOI: | 10.1002/jbm.b.30227 |
Abstrakt: | Poly(ethylene oxide) (PEO) coatings have been shown to reduce the adhesion of different microbial strains and species and thus are promising as coatings to prevent biomaterial-centered infection of medical implants. Clinically, however, PEO coatings are not yet applied, as little is known about their stability and effectiveness in biological fluids. In this study, PEO coatings coupled to a glass substratum through silyl ether bonds were exposed for different time intervals to saliva, urine, or phosphate-buffered saline (PBS) as a reference at 37 degrees C. After exposure, the effectiveness of the coatings against bacterial adhesion was assessed in a parallel plate flow chamber. The coatings appeared effective against Staphylococcus epidermidis adhesion for 24, 48, and 0.5 h in PBS, urine, and saliva, respectively. Using XPS and contact-angle measurements, the variations in effectiveness could be attributed to conditioning film formation. The overall short stability results from hydrolysis of the coupling of the PEO chains to the substratum. ((c) 2005 Wiley Periodicals, Inc.) |
Databáze: | MEDLINE |
Externí odkaz: |