Autor: |
Sasai N; Department of Radiology, Okayama University Graduate School of Medicine and Dentistry, Okayama 700-8558, Japan. nsasai@mac.com, Togami I, Tsunoda M, Sei T, Akaki S, Hiraki Y |
Jazyk: |
angličtina |
Zdroj: |
Acta medica Okayama [Acta Med Okayama] 2003 Aug; Vol. 57 (4), pp. 163-70. |
DOI: |
10.18926/AMO/32808 |
Abstrakt: |
Chemical shift MRI is widely used for identifying adenomas, but it is not a perfect method. We determined whether combined dynamic MRI methods can lead to improved diagnostic accuracy. Fifty-seven adrenal masses were examined by chemical shift and dynamic MR imaging using 2 MR systems. The masses included 38 adenomas and 19 non-adenomas. In chemical shift MRI studies, the signal intensity index (SI) was calculated, and the lesions classified into 5 types in the dynamic MRI studies. Of the 38 adenomas studied, 37 had an SI greater than 0. In the dynamic MRI, 34 of 38 adenomas showed a benign pattern (type 1). If the SI for the adenomas in the chemical shift MRI was considered to be greater than 0, the positive predictive value was 0.9, and the negative predictive value was 0.94 and kappa = 0.79. If type 1 was considered to indicate adenomas in the dynamic MRI, the corresponding values were 0.94, 0.81 and kappa = 0.77 respectively. The results obtained when the 2 methods were combined were 1, 0.95 and kappa = 0.96 respectively. The chemical shift MRI was found to be useful for identifying adenomas in most cases. If the adrenal mass had a low SI (0 < SI < 5), dynamic MRI was also found to be helpful for making a differential diagnosis. |
Databáze: |
MEDLINE |
Externí odkaz: |
|