High dose rate (192)Ir afterloading brachytherapy for cancer of the vagina.

Autor: Kushner DM; Department of Obstertrics and Gynecology, University of Wisconsin Hospital and Clinics, H4/636 CSC, 600 Highland Avenue, Madison, WI 53792-3236, USA., Fleming PA, Kennedy AW, Wilkinson DA, Lee E, Saffle PA
Jazyk: angličtina
Zdroj: The British journal of radiology [Br J Radiol] 2003 Oct; Vol. 76 (910), pp. 719-25.
DOI: 10.1259/bjr/15634046
Abstrakt: We report results of brachytherapy for carcinoma of the vagina, utilizing a Nucletron high dose rate system for Delclos Vaginal Applicators (cylinder) and Syed Template Applicators (interstitial). The linear quadratic (LQ) model was used to determine the optimum time-dose-fractionation schedules. Interstitial doses were determined at the isodose line that included gross tumour. Cylinder doses were determined either at the vaginal surface (5 cases), at 0.5 cm depth (5 cases), or at 1.0 cm depth (1 case). For the first treatment (n=19), interstitial templates were utilized in 8 patients and vaginal cylinders in 11. 11 patients received second treatments: 6 templates and 5 cylinders. The median dose of external beam radiation (n=15) was 40.0 Gy followed, after a median 23 day interval, by high dose rate brachytherapy (HDRB) of 4 fractions in 30-42 h; then a median interval gap of 25 days, followed by repeat HDRB. The median total fractionated HDRB dose per patient was 23.0 Gy (range: 6.9 Gy to 40.4 Gy; calculated low dose rate equivalent of 29.8 Gy). Tumour histologies included 14 squamous cell carcinomas, 2 adenocarcinomas, 2 melanomas, and 1 small cell tumour. Three patients experienced early brachytherapy-related complications (diarrhoea, dysuria and labial dermatitis). Three patients (15.8%) developed serious/late complications including ureteral stenosis, painful vaginal necrosis and small bowel obstruction. The first of these patients received 2 templates, the second a cylinder followed by a template and a cylinder, and the third a single cylinder. The 2 year progression-free survival was 39.3% (median 15.7 months), while the 2 year overall survival was 66.1% (median 29.9 months). (192)Ir afterloading HDRB is a feasible approach to women with vaginal cancer with acceptable toxicity and tumour response. Potential advantages include patient preference, outpatient cost-effectiveness in the case of cylinder technique, and no radiation exposure to hospital personnel. Long-term follow-up is needed to further assess late complications, and larger studies are needed to confirm our results.
Databáze: MEDLINE