Excimer laser coronary angioplasty and intracoronary radiation for in-stent restenosis: six-month angiographic and clinical outcomes.
Autor: | Ajani AE; Catheterization Laboratories, Washington Hospital Center, Suite 4B-1, 110 Irving Street Northwest, Washington, DC 20010, USA., Waksman R, Kim HS, Satler LF, Pichard AD, Kent KM, Porrazzo M, White RL, Pinnow EE, Lindsay JR |
---|---|
Jazyk: | angličtina |
Zdroj: | Cardiovascular radiation medicine [Cardiovasc Radiat Med] 2001 Jul-Sep; Vol. 2 (3), pp. 191-6. |
DOI: | 10.1016/s1522-1865(01)00087-7 |
Abstrakt: | Background: The purpose of this study was to evaluate 6-month clinical and angiographic outcomes in patients treated with excimer laser coronary angioplasty (ELCA) and intracoronary radiation (ICR) for in-stent restenosis (ISR). Methods: A consecutive series of 175 patients with ISR treated with ELCA+ICR (gamma and beta emitters) were compared to 33 patients with ISR treated with ELCA alone. Baseline characteristics were similar between groups. ELCA+ICR and ELCA-alone patients had similar lesion lengths (25.0+/-12.0 vs. 24.0+/-16.8 mm, P=NS) in predominantly saphenous vein grafts (SVG, 38% vs. 42%, P=NS). Results: Procedural success was high (ELCA+ICR, 97.0% vs. ELCA alone, 98.5%, P=NS), with no perforations or acute vessel closures. ELCA+ICR therapy reduced target vessel revascularization (TVR; 27% vs. 64%, P<.0001) and major adverse cardiac events [MACE: death, myocardial infarction (MI), or TVR; 30% vs. 64%, P<.0001] compared to ELCA alone. Late loss was 0.66+/-0.90 mm in ELCA+ICR patients and 0.85+/-0.60 mm in ELCA-alone patients (P=NS). Angiographic binary restenosis (>50%) was significantly reduced with adjunctive ICR (28% vs. 54%, P=.014). Conclusion: Radiation therapy with ELCA significantly reduces angiographic binary restenosis at 6 months in patients with diffuse ISR, driven predominantly by reduced percutaneous TVR. |
Databáze: | MEDLINE |
Externí odkaz: |