Autor: |
Olszewska AM; Medical Physics Department, M. Sklodowska-Curie Memorial Cancer Center, W.K. Roentgen 5, 02-781, Warsaw, Poland., Saarnak AE, de Boer RW, van Bunningen BN, Steggerda MJ |
Jazyk: |
angličtina |
Zdroj: |
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology [Radiother Oncol] 2001 Oct; Vol. 61 (1), pp. 83-5. |
DOI: |
10.1016/s0167-8140(01)00400-5 |
Abstrakt: |
The correlation between dose values from dose-volume histograms (DVHs) and dose values from dose-wall histograms (DWHs) of the rectum tissue of patient with uterine cervix cancer was determined. The minimum dose in 2 cm3 in the high-dose region of the DVH is a good estimate of the dose in the rectum wall. |
Databáze: |
MEDLINE |
Externí odkaz: |
|