Motion artefact in voltage-sensitive fluorescent dye emission during repeated ischemia of isolated heart.
Další autoři: |
Kolářová, Jana, 1976-
Nováková, Marie, 1965-
Provazník, Ivo, 1968-
|
---|---|
Jazyk: | angličtina |
Předmět: | |
Druh dokumentu: | Kniha |
Abstrakt: | Abstract: Motion artefact (MA) in voltage-sensitive fluorescent signals causes significant debasement of action potential. During ischemia and reperfusion in isolated rabbit heart, this artefact develops in a manner which may be described by the time of its onset, level, and shape. The MA during ischemia: (a) may become substantial with approximately two minutes delay after establishing global ischemia; (b) may be almost twice as high as the physiological action potential and decreases both with time and repetition of ischemia; (c) the MA shape is unpredictable and depends on individual rabbit. |