Autor: |
Sullivan, David W.1 sullivan231@mail.utexas.edu, Price, James H.2, Lambeth, Bryan2, Sheedy, Keith A.2, Savanich, Kasey2, Tropp, Richard J.3 |
Předmět: |
|
Zdroj: |
Journal of the Air & Waste Management Association (Taylor & Francis Ltd). Sep2013, Vol. 63 Issue 9, p1070-1082. 13p. |
Abstrakt: |
When annual average PM2.5(fine particulate matter sized 2.5 microns and less) data for 2005 became available in April 2006 and the 3-yr average PM2.5concentration in an area just north of the Houston Ship Channel reached 15.0 µg/m3, the Texas Commission on Environmental Quality (TCEQ) initiated daily collection of quartz fiber as well as Teflon PM2.5filter samples for chemical speciation analysis. The purpose of the chemical speciation analysis was to use the speciation data, together with meteorological data and hourly TEOM (tapered element oscillating microbalance) PM2.5mass data, to identify the causes of the high PM2.5concentrations affecting the monitoring site and the neighborhood. The ultimate purpose was to target emission reduction efforts to sources contributing to the high measured PM2.5concentrations. After a year of data collection, it was recognized that a specific source, unpaved driveways and loading areas along the Ship Channel and dirt tracked onto Clinton Drive, the main artery running east-west north of the Ship Channel, were the primary cause for the Clinton Drive site's measuring PM2.5concentrations significantly higher than other sites in Houston. The source characterization and remediation steps that have led to sustained reduced concentrations are described in this paper. [ABSTRACT FROM AUTHOR] |
Databáze: |
GreenFILE |