Autor: |
Patel, Sumer Singh1 (AUTHOR) patelsumer@gmail.com, Lanjewar, Atul1 (AUTHOR) |
Předmět: |
|
Zdroj: |
International Journal of Sustainable Engineering. Apr2021, Vol. 14 Issue 2, p162-171. 10p. |
Abstrakt: |
This paper presents an experimental investigation of heat transfer and friction factor in a rectangular duct with discrete V-rib integrated with staggered elements. The Reynolds number (Re) of 3000–12,000, ratio of staggered element size to rib height (r/e) of 2–5.5, relative roughness pitch (p/e) of 12, relative roughness height (e/Dh) of 0.045, flow angle of attack (α) of 60°, relative gap width (g/e) of 1, relative staggered element position (p'/p) of 0.65 and number of gaps (Ng) of 6. The maximum augmentation in Stanton number is 1.90 times over the smooth duct and maximum thermal efficiency is obtained 86% corresponding to ratio of staggered element size to rib height (r/e) of 3.5. [ABSTRACT FROM AUTHOR] |
Databáze: |
GreenFILE |
Externí odkaz: |
|