Fine Particle (PM[sub 2.5]) Measurement Methodology, Quality Assurance Procedures, and Pilot Results of the EXPOLIS Study.

Autor: Koistinen, Kimmo J.1, Kousa, Anu1, Tenhola, Virpi1, Hänninen, Otto1, Jantunen, Matti J.1, Oglesby, Lucy2, Kuenzli, Nino2, Georgoulis, Lambros3
Předmět:
Zdroj: Journal of the Air & Waste Management Association (Air & Waste Management Association). Oct99, Vol. 49 Issue 10, p1212-1220. 9p. 2 Black and White Photographs, 2 Charts, 4 Graphs.
Abstrakt: EXPOLIS is a European multicenter (Athens, Basel, Grenoble, Helsinki, Milan, and Prague) air pollution exposure study. It is the first international, population-based, large-scale study, where personal exposures to PM[sub2.5] aerosol particles (together with volatile organic compounds and carbon monoxide) are being monitored. EXPOLIS is performed in six different centers across Europe, the sampled aerosol concentrations vary greatly, and the microenvironmental samples are not collected with the same equipment as the personal samples. Therefore careful equipment selection, methods development and testing, and thorough quality assurance and quality control (QA & QC) procedures are essential for producing reliable and comparable PM[sub2.5] data. This paper introduces the equipment, the laboratory test results, the pilot results, the standard operating procedures, and the QA & QC procedures of EXPOLIS. Test results show good comparability and repeatability between personal and microenvironmental monitors for PM[sub2.5] at different concentration levels measured across Europe in EXPOLIS centers. [ABSTRACT FROM AUTHOR]