2,576 Ultrasounds for Blunt Abdominal Trauma

Autor: Dolich, Matthew O., McKenney, Mark G., Varela, J. Esteban, Compton, Raymond P., McKenney, Kimberly L., Cohn, Stephen M.
Předmět:
Zdroj: ETSU Faculty Works.
Druh dokumentu: Text
DOI: 10.1097/00005373-200101000-00019
Popis: Background: Determination of intra-abdominal injury following blunt abdominal trauma (BAT) continues to be a diagnostic challenge. Ultrasound (US) bas been described as a potentially useful diagnostic tool in this setting and is being used with increasing frequency in trauma centers. We determined the diagnostic capability of US in the evaluation of BAT. Methods: A retrospective analysis of our trauma US database was performed over a 30-month period. Computed tomographic scan, diagnostic peritoneal lavage, or exploratory laparotomy confirmed the presence of intra-abdominal injury. Results: During the study period, 8,197 patients were evaluated at the Ryder Trauma Center. Of this group, 2,576 (31%) had US in the evaluation of BAT. Three hundred eleven (12%) US exams were considered positive. Forty-three patients (1.7%) had a false-negative US; of this group, 10 (33%) required exploratory laparotomy. US had a sensitivity of 86%, a specificity of 98%, and an accuracy of 97% for detection of intra-abdominal injuries. Positive predictive value was 87% and negative predictive value was 98%. Conclusion: Emergency US is highly reliable and may replace computed tomographic scan and diagnostic peritoneal lavage as the initial diagnostic modality in the evaluation of most patients with BAT.
Databáze: Networked Digital Library of Theses & Dissertations