Early Efficacy of Combined Total Ankle Total Talus Replacement (TATR) in the Revision Setting

Autor: Jonathan Day MD, Joyce En-Hua Wang BS, Kory Pasko BS, Julia McCann MD, Paul Cooper MD
Jazyk: angličtina
Rok vydání: 2023
Předmět:
Zdroj: Foot & Ankle Orthopaedics, Vol 8 (2023)
Druh dokumentu: article
ISSN: 2473-0114
24730114
DOI: 10.1177/2473011423S00091
Popis: Category: Ankle Arthritis; Ankle Introduction/Purpose: Revision of failed total ankle replacement (TAR), such as in the setting of implant subsidence, aseptic loosening, or avascular necrosis (AVN) of the talus can be challenging and associated with increased morbidity. As TAR becomes a more commonly performed procedure in the treatment of end-stage ankle arthritis (ESAA), naturally there arises the need for revision options. In this case series, we describe the short-term clinical and radiographic outcomes of using a patient-specific custom 3D-printed total ankle total talus (TATR) prosthesis in the treatment of this unique subset of patients. Methods: 29 patients with ESAA who underwent TATR by a single surgeon at our institution from 2019 to 2022 were retrospectively identified. Average age was 61.3 (range, 39-77) years, with average follow-up of 22.5 (range, 12 to 57) months. All patients were indicated for revision of primary STAR implant (Stryker, Kalamazoo, MI) for failed TAR in the setting of aseptic loosening/subsidence and/or talar AVN. All patients underwent replacement with 3D-printed titanium implants based on preoperative CT analysis (Additive Orthopaedics, Little Silver, NJ). Custom components included a combined total talus and stemmed tibial component through an anterior approach (Figure). Pre- and postoperative patient-reported outcome were assessed using Patient Reported Outcomes Measurement Information System (PROMIS). Pre- and postoperative implant alignment was assessed using medial distal tibial angle (MDTA) and tibiotalar angle (TTA) on anteroposterior, and sagittal tibial angle (STA) on lateral weightbearing plain films. Incidence of revision and reoperations were recorded. Results: At final follow-up, all custom implants were intact without evidence of hardware failure or implant subsidence. There was significant improvement in all six PROMIS domains (Table). Two patients (6.9%) had postoperative complications; one patient underwent open reduction internal fixation of the tibia for a tibial periprosthetic fracture 1 month postoperatively, another patient underwent medial gutter debridement and tarsal tunnel release for recurrent pain 14 months postoperatively. There were no significant differences in pre- to postoperative radiographic coronal or sagittal alignment in terms of MDTA (88.4 vs 88.8), TTA (87.3 vs 88.0), or STA (85.1 vs 85.9). Conclusion: As ankle replacement becomes a more popular surgical treatment for ESAA, there is a growing need to identify durable revision solutions. This study demonstrates the promising utility of custom 3D-printed TATR in the setting of revision TAR. At short-term follow-up, there was significant improvement in pain and physical function, with an acceptable postoperative complication rate. While preliminary, custom 3D-printed TATR offer an alternative solution for a unique subset of patients where there are limited options available for revision following failed primary TAR. Further longer-term follow-up with a larger cohort is underway.
Databáze: Directory of Open Access Journals