Anatomical and Biomechanical Stability of Single/Double Screw‐Cancellous Bone Fixations of Regan–Morry Type III Ulnar Coronoid Fractures in Adults: CT Measurement and Finite Element Analysis
Autor: | Hao Ye, Yongchao Yang, Tingyang Xing, Guirong Tan, Shuxun Jin, Zhichao Zhao, Weikang Zhang, Yanyan Li, Lei Zhang, Jianshun Wang, Rongmei Zheng, Yun Lu, Lijun Wu |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2023 |
Předmět: | |
Zdroj: | Orthopaedic Surgery, Vol 15, Iss 4, Pp 1072-1084 (2023) |
Druh dokumentu: | article |
ISSN: | 1757-7861 1757-7853 09495320 |
DOI: | 10.1111/os.13664 |
Popis: | Objective At present, it is still uncertain whether single screw has the same stability as double screws in the treatment of ulnar coronal process basal fracture (Regan–Morry type III). So, we aimed to compare the pull‐out force and anti‐rotation torque of anterior single/double screw‐cancellous bone fixation (aSSBF, aDSBF) in this fracture, and further study the influencing factors on anatomical and biomechanical stability of smart screw internal fixations. Methods A total of 63 adult volunteers with no history of elbow injury underwent elbow CT scanning with associated three‐dimensional reconstruction that enabled the measurements of bone density and fixed length of the proximal ulna and coronoid. The models of coronal process basal fracture, aSSBF and aDSBF, were developed and validated. Using the finite element model test, the sensitivity analysis of pull‐out force and rotational torque was carried out. Results The pull‐out force of aSSBF model was positively correlated with the density of the cancellous bone and linearly related to the fixed depth of the screw. The load pattern of pull‐out force of aDSBF model was similar to that of aSSBF model. The ultimate torque of aDSBF model was higher than that of aSSBF model, but the load pattern of ultimate torque of both models was similar to each other when the fracture reset was satisfactory, and the screw nut attaches closely to coronoid process. Moreover, with enhancement of initial pre‐tightening force, the increase of ultimate torque of both models was small. Conclusions In addition to three pull‐out stability factors of smart screw fixations, fracture surface fitting degree and nut fitting degree are the other two important anatomical and biomechanical stability factors of smart screw fixations both for rotational stability. When all pull‐out stability and rotational stability factors meet reasonable conditions simultaneously, single or double screw fixation methods are stable for the treatments of ulnar coronoid basal fractures. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |