Efficacy of stylet angulation at the holding position during tracheal intubation with a videolaryngoscope: a randomized controlled trial
Autor: | Ryo Wakabayashi, Yuki Shiko, Tomofumi Kodaira, Yuko Shiroshita, Hitomi Otsuka, Kosuke Baba, Norimasa Hishinuma |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: | |
Zdroj: | Scientific Reports, Vol 11, Iss 1, Pp 1-8 (2021) |
Druh dokumentu: | article |
ISSN: | 2045-2322 49738240 |
DOI: | 10.1038/s41598-021-00115-x |
Popis: | Abstract The aim of this randomized controlled trial was to determine the efficacy of stylet angulation at the holding position during tracheal intubation with a McGRATH MAC videolaryngoscope. Patients were randomized to a group for intubation without stylet angulation at the holding position (non-angulation group) and to a group for intubation with stylet angulation at the holding position (angulation group). The primary outcome was the time for placement of the tracheal tube. Sixty patients were analyzed. The mean (standard deviation) times for tube placement were 21.3 (5.6) s in the non-angulation group and 16.9 (3.8) s in the angulation group (P |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |