Popis: |
Advanced adiabatic compressed air energy storage (AA-CAES) is a clean large-scale physical energy storage technology. Compared with other energy storage technologies, AA-CAES can supply and store multi-carrier energy, which makes it have abroad prospective in the application in micro integrated energy system. Considering the multi-carrier energy generation characteristic of AA-CAES power plant, the optimal dispatch strategy of micro integrated energy system with AA-CAES power plant was studied. The basic composition of the micro integrated energy system with AA-CAES power plant was introduced. Based on the actual thermodynamic process of the AA-CAES power plant, a combined dispatch model of multi-carrier energy flow of cooling, heating and power was established. On this basis, the optimal dispatch model of micro integrated energy system with AA-CAES power plant was established to minimize the operating cost of the system. In the end, based on the operation data of Sino-Singapore ecologic town in Tianjin, the simulation test was carried out for model validation. |