Objective: To evaluate the surgical outcomes and predictors of failure of Single Incision Mini Sling (Ophira) in women with urodynamic stress incontinence. Materials and methods: Records of 115 women underwent anti-incontinence procedure using Ophira Mini Sling from June 2019 to September 2020 reviewed. Subjective evaluation was assessed using validated IIQ-7, UDI-6, POPDI-6 and PISQ-12 questionnaires. Multichannel urodynamics, 1-h pad test and 72-h voiding diary was performed as objective evaluation. Primary outcome was the objective cure rate of negative urine leak on provocative filling cystometry and 1-h pad test weight 66 years, presence of asthma, pre-operative Intrinsic Sphincter Deficiency (ISD), and Maximum Urethral Closure Pressure (MUCP) value |