Popis: Abstract Echinoderm microtubule-associated protein 4 (EML4) - anaplastic lymphoma kinase (ALK) fusion gene detection is of great significance in personalized tumor treatment. With the development of EML4-ALK fusion variants detection, it is necessary to establish traceability to ensure the consistency and comparability of its detection results in clinical practice. The establishment of traceability relies on SI traceable reference materials (RMs) and potential reference measurement procedures (RMPs). In this study, a potential RMP for the quantitative detection of V1 and V3 fusion mutations and the reference type (ALK-ref, including wild type, V1 and V3 mutant type) based on reverse transcription dPCR (RT-dPCR) and EML4-ALK fusion gene RMs were established. The proposed potential RMP has high specificity, good inter-laboratory reproducibility (CV