Challenges in Removing the Essure® Device
Autor: | Daniëlle M. van Gastel, Liselotte W. Maassen, Carolien A. M. Koks, Sebastiaan Veersema, Marlies Y. Bongers |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: | |
Zdroj: | Case Reports in Obstetrics and Gynecology, Vol 2020 (2020) |
Druh dokumentu: | article |
ISSN: | 2090-6684 2090-6692 |
DOI: | 10.1155/2020/8823606 |
Popis: | We present a case about Essure® removal surgery in which the third markers of the device have torn off. The woman needed a second surgery for complete removal of the devices. Fluoroscopy during surgery is a good method to visualize the lost fragments. With fluoroscopy, a hysterectomy is not needed for complete removal. It is important to understand the structure of the device and to be aware of the four radiopaque markers during surgery and their removal. |