Autor: |
V.B. Murali Krishna, V. Sandeep, Narendra B.K., K.R.K.V. Prasad |
Jazyk: |
angličtina |
Rok vydání: |
2023 |
Předmět: |
|
Zdroj: |
Results in Engineering, Vol 18, Iss , Pp 101182- (2023) |
Druh dokumentu: |
article |
ISSN: |
2590-1230 |
DOI: |
10.1016/j.rineng.2023.101182 |
Popis: |
Induction generators have been gaining popularity since the last few decades for the small -scale off-grid power generation renewable energy applications due to many inherent advantages. The IG is not a self-started generator in off-grid mode of operation to generate the required voltage because of isolation from the grid to supply the required amount of reactive power to the generator. In this context, the self-excitation process in the induction generator mainly depends on the amount of reactive power, then speed of the rotor, and load on the system. In this paper, the effect of these three parameters on the performance of the self-excited induction generator is experimentally studied. The focus of the paper is to identify the best configuration of generator operation to carry out the maximum loading capacity and economical operation. Further, the proposed study is extended for an extra initial excitation approach and verified the performance under the same source and load condition and derived some key aspects for utilization of the generator at its maximum loading capacity. A micro-hydro source driven turbine emulations used as an input source to the SEIG in this experimental work. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|