Autoclaved aerated concrete reinforced by polymeric pins
Autor: | A. Behenck Aramburu, R. de Avila Delucis, S. Campos Amico |
---|---|
Jazyk: | English<br />Spanish; Castilian |
Rok vydání: | 2024 |
Předmět: | |
Zdroj: | Materiales de Construccion, Vol 74, Iss 355 (2024) |
Druh dokumentu: | article |
ISSN: | 0465-2746 1988-3226 |
DOI: | 10.3989/mc.2024.370623 |
Popis: | Autoclaved Aerated Concrete (AAC) is a lightweight and sustainable building material known for its thermal insulation and acoustic properties. However, its relatively low mechanical strength limits its use in load-bearing applications. This paper introduces the concept of incorporating unsaturated polyester resin (UPR) pins into AAC blocks to improve compressive and flexural strength of the material. Pin diameters of 4, 6, 8 and 10 mm were studied, oriented at 90° and 45° in relation to the AAC main plane. The effects of the UPR/AAC interface were analyzed through microscopy. The results point to a substantial increase in mechanical strength of the reinforced AAC, wherein smaller pins with orientation of 45° and 90° presented the best behavior under flexural (up to 298%) and compressive loading (up to 183%), respectively. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |