Popis: | Objectives:This study aimed to achieve improved process performance and energy saving by developing a technology to control the air supply of an aerobic basin by measuring the conductivity in the anoxic basin. Methods:To verify whether conductivity can be used as an operation indicator of biological treatment, the correlation analysis between water quality factor and conductivity of each process was conducted by dividing into summer (methanol input), winter and autumn periods. An empirical formula was presented by briefly arranging the required air quantity formula, and a quick reference was prepared by putting air supply in the conductivity range sequentially. The performance evaluation was judged based on the removal efficiency of ammonia nitrogen and total inorganic nitrogen, SNR and SDNR, the change of air supply, the stability of the process against inflow change. Results and Discussion:The seasonal correlation coefficients of conductivity and water quality items were calculated in the order of ammonia nitrogen, total inorganic nitrogen, DOC, and phosphate in the range of 0.5267~0.9115. It was found that the conductivity could be used as an operation indicator of the biological treatment process with a correlation coefficient of 0.5 or more. The regression equations for the conductivity and ammonia nitrogen are secured by season, so it is possible to estimate the ammonia nitrogen through the conductivity. At the end of the aerobic basin DO was 3.4 mg/L, the nitrogen treatment efficiency in winter was the best. The aerobic basin DO can be controlled by the air supply, and it can be seen that it is possible to control the air supply and improve the nitrogen treatment efficiency by directly measuring the conductivity having a high correlation with nitrogen. An empirical formula for estimating the required air volume through conductivity and inflow is presented. A' and (B' + X') are 0.0589 (m3-air/h)/(m3/h)/(µS/cm) and –77.562 (m3-air/h)/(m3/h). The result of automatic control of air supply according to the measured conductivity of anoxic tank during winter season showed that total inorganic nitrogen removal efficiency and SDNR were 8.3% and 0.007 g-N/g-MLSS/d higher than the actual plant conditions, respectively. During the automatic control period, the air supply/inflow average ratio was 36 (m3-air/h)/(m3/h), which could reduce the air supply by 21.7% compared to the actual plant conditions. Conclusions:The air supply can be estimated from the flow rate and conductivity. The air supply control technology of the conductivity-based MLE process will be able to simultaneously improve nitrogen removal efficiency and reduce energy consumption. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |