Torque Analysis of a Triple Acid-Etched Titanium Implant Surface
Autor: | Ana Emília Farias Pontes, Cássio Torres de Toledo, Valdir Gouveia Garcia, Fernando Salimon Ribeiro, Celso Eduardo Sakakura |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: | |
Zdroj: | The Scientific World Journal, Vol 2015 (2015) |
Druh dokumentu: | article |
ISSN: | 2356-6140 1537-744X |
DOI: | 10.1155/2015/819879 |
Popis: | The present study aimed to evaluate the removal torque of titanium implants treated with triple acid etching. Twenty-one rats were used in this study. For all animals, the tibia was prepared with a 2 mm drill, and a titanium implant (2 × 4 mm) was inserted after treatment using the subtraction method of triple acid etching. The flaps were sutured. Seven animals were killed 14, 28, and 63 days after implant installation, and the load necessary for removing the implant from the bone was evaluated by using a torque meter. The torque values were as follows: 3.3 ± 1.7 Ncm (14 days), 2.2 ± 1.3 Ncm (28 days), and 6.7 ± 1.4 Ncm (63 days). The torque value at the final healing period (63 days) was statistically significantly different from that at other time points tested (ANOVA, p=0.0002). This preliminary study revealed that treatment with triple acid etching can create a promising and efficient surface for the process of osseointegration. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |