A new approach to instantaneous power based control of DFIG using active disturbance rejection control

Autor: Shibani Prasad Mohapatra, Pradipta Kishore Dash, Ranjeeta Bisoi
Jazyk: angličtina
Rok vydání: 2024
Předmět:
Zdroj: e-Prime: Advances in Electrical Engineering, Electronics and Energy, Vol 9, Iss , Pp 100740- (2024)
Druh dokumentu: article
ISSN: 2772-6711
DOI: 10.1016/j.prime.2024.100740
Popis: This paper presents the design and control of a wind energy converter system that uses a doubly fed induction generator. It introduces a model that incorporates instantaneous active and reactive power as state variables to represent both the stator and rotor sides of the doubly fed induction generator. Subsequently, a linear active disturbance rejection-based control regulator is proposed for the control loops. The parameters of the linear active disturbance rejection controllers (ADRC) are adjusted by two methods: the single parameter tuning approach and the genetic algorithm (GA) method. The performance of the suggested controller is ultimately compared with a tuned proportional-integral (PI) control regulator in the MATLAB environment. In order to examine the performance of the system, various test scenarios are taken into account. These scenarios include different percentages of load change in both sub-synchronous and super-synchronous modes of operation, faults with different fault periods are considered in both modes of operation. The conventional PI controller-based approach requires 35 control cycles to reach steady state under load change conditions and 50 control cycles under symmetrical fault conditions, regardless of whether the system is operating in sub synchronous or super synchronous mode. The single parameter-based tuned ADRC approach only requires 15 control cycles for load change and 20 control cycles for symmetrical fault scenarios. In contrast, for both the load change and symmetrical fault scenarios, the ADRC with GA-based parameter tuning reaches steady state in just 5 control cycles. Furthermore, a case involving wind speed variation is presented to demonstrate the maximum power point tracking capability of the proposed control structure. Similarly, for the robustness test of the control regulator, variations in resistance and inductance are introduced to observe their impact on the response of the control regulators. Finally, a real-time hardware in loop setup is presented to validate the control strategy during the load change in the sub-synchronous mode of operation of the doubly fed induction generator.
Databáze: Directory of Open Access Journals