Autor: |
Youngwon Kim, Seokha Yoo, Sun-Kyung Park, Hansu Bae, Young-Jin Lim, Jin-Tae Kim |
Jazyk: |
angličtina |
Rok vydání: |
2021 |
Předmět: |
|
Zdroj: |
BMC Anesthesiology, Vol 21, Iss 1, Pp 1-8 (2021) |
Druh dokumentu: |
article |
ISSN: |
1471-2253 |
DOI: |
10.1186/s12871-021-01444-0 |
Popis: |
Abstract Background Spondylolisthesis is a common degenerative spinal deformity. At the level of spondylolisthesis, the anatomy of the interlaminar space may differ from normal spine, in which case optimal angle of the needle insertion for spinal anesthesia may change. This study compared the optimal angle of needle insertion during spinal anesthesia in patients with and without lumbar spondylolisthesis using ultrasound. Methods We recruited 40 patients, 20 with and 20 without lumbar spondylolisthesis (group S and N, respectively). Ultrasonography was performed in the transverse midline and parasagittal oblique views at the spondylolisthesis level and the adjacent upper level. We measured the probe application angle with the longest interlaminar height of the ligamentum flavum-dura mater complex (LFD), depth from the skin to the LFD, depth from the skin to the anterior complex, and intrathecal space width. A positive angle represented a cephalad angulation. Results The optimal needle insertion angle in the transverse midline view at the spondylolisthesis level was (-) 2.7 ± 3.4° in group S and 0.8 ± 2.5° in group N (P $$ |
Databáze: |
Directory of Open Access Journals |