Evaluation of a generalized knowledge-based planning performance for VMAT irradiation of breast and locoregional lymph nodes-Internal mammary and/or supraclavicular regions.

Autor: Maria Rago, Lorenzo Placidi, Mattia Polsoni, Giulia Rambaldi, Davide Cusumano, Francesca Greco, Luca Indovina, Sebastiano Menna, Elisa Placidi, Gerardina Stimato, Stefania Teodoli, Gian Carlo Mattiucci, Silvia Chiesa, Fabio Marazzi, Valeria Masiello, Vincenzo Valentini, Marco De Spirito, Luigi Azario
Jazyk: angličtina
Rok vydání: 2021
Předmět:
Zdroj: PLoS ONE, Vol 16, Iss 1, p e0245305 (2021)
Druh dokumentu: article
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0245305
Popis: PurposeTo evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions.Methods and materialsSix RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure. Five more models, twins of the previous models, have been created without the need of these structures.ResultsAll models were successfully validated on an independent cohort of 40 patients, 30 from the same institute that provided the training patients and 10 from an additional institute, with the resulting plans being of equal or better quality compared with the clinical plans. The internal validation shows that the models reduce the heart maximum dose of about 2 Gy, the mean dose of about 1 Gy and the V20Gy of 1.5 Gy on average. Model R and L together with model B without optimization structures ensured the best outcomes in the 20% of the values compared to other models. The external validation observed an average improvement of at least 16% for the V5Gy of lungs in RP plans. The mean heart dose and for the V20Gy for lung IPSI were almost halved. The models reduce the maximum dose for the spinal canal of more than 2 Gy on average.ConclusionsAll KB models allow a homogeneous plan quality and some dosimetric gains, as we saw in both internal and external validation. Sub-KB models, developed by splitting right and left breast cases or including only whole breast with locoregional lymph nodes, have shown good performances, comparable but slightly worse than the general model. Finally, models generated without the optimization structures, performed better than the original ones.
Databáze: Directory of Open Access Journals
Nepřihlášeným uživatelům se plný text nezobrazuje