Autor: |
Onno J Arntz, Bartijn C H Pieters, Peter L E M van Lent, Marije I Koenders, Peter M van der Kraan, Fons A J van de Loo |
Jazyk: |
angličtina |
Rok vydání: |
2020 |
Předmět: |
|
Zdroj: |
PLoS ONE, Vol 15, Iss 7, p e0236508 (2020) |
Druh dokumentu: |
article |
ISSN: |
1932-6203 |
DOI: |
10.1371/journal.pone.0236508 |
Popis: |
Extracellular vesicles (EVs) are cell membrane-derived phospholipid bilayer nanostructures that contain bioactive proteins, enzymes, lipids and polymers of nucleotides. They play a role in intercellular communication and are present in body fluids. EVs can be isolated by methods like ultracentrifugation (UC), polyethylene-glycol-precipitation (PEG) or size exclusion chromatography (SEC). The co-presence of immunoglobulins (Ig) in EV samples isolated from plasma (pEVs) is often reported and this may influence the assessment of the biological function and phenotype of EVs in bio- and immunoassay. Here, we studied the presence of an Ig-based therapeutic (etanercept) in pEV samples isolated from rheumatoid arthritis (RA) patients and improved the isolation method to obtain purer pEVs. From plasma of etanercept (Tumor-necrosis-factor (TNF)-α antibodies)-treated RA patients pEVs were isolated by either UC, PEG or SEC. SEC isolated pEVs showed the highest particle-to-protein ratio. Strong TNF-α inhibition determined in a TNF-α sensitive reporter assay was observed by pEVs isolated by UC and PEG, and to a lesser extent by SEC, suggesting the presence of functional etanercept. SEC isolation of etanercept or labelled immunoglobulin G (IgG) showed co-isolation of these antibodies in the pEV fraction in the presence of plasma or a high protein (albumin) concentration. To minimize the presence of etanercept or immunoglobulins, we extended SEC (eSEC) column length from 56mm to 222mm (total stacking volume unchanged). No effect on the amount of isolated pEVs was observed while protein and IgG content were markedly reduced (90%). Next, from six etanercept- treated RA patients, pEVs were isolated on a eSEC or standard SEC column, in parallel. TNF-α inhibition was again observed in pEVs isolated by conventional SEC but not by eSEC. To confirm the purer pEVs isolated by eSEC the basal IL-8 promoter activation in human monocytes was determined and in 4 out of 5 SEC isolated pEVs activation was observed while eSEC isolated pEVs did not. This study shows that extended SEC columns yielded pEVs without detectable biologicals and with low protein and IgG levels. This isolation method will improve the characterization of pEVs as potential biomarkers and mediators of disease. |
Databáze: |
Directory of Open Access Journals |
Externí odkaz: |
|
Nepřihlášeným uživatelům se plný text nezobrazuje |
K zobrazení výsledku je třeba se přihlásit.
|