Efeitos do ultra-som de baixa intensidade na veia auricular de coelhos Effects of low intensity ultrasound in the auricular vein of rabbits
Autor: | Marcelo Araújo, José Carlos Costa Baptista-Silva, Paulo de Oliveira Gomes, Humberto de Oliveira Campos, Neil Ferreira Novo, Yara Juliano |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2003 |
Předmět: | |
Zdroj: | Acta Cirúrgica Brasileira, Vol 18, Iss 1, Pp 01-17 (2003) |
Druh dokumentu: | article |
ISSN: | 0102-8650 1678-2674 56799098 |
DOI: | 10.1590/S0102-86502003000100006 |
Popis: | OBJETIVO: Estudar a ação do ultra-som na veia auricular de coelhos. MÉTODOS: Vinte coelhos foram divididos em dois grupos de dez animais diferindo com relação ao local da aplicação, do ultra-som, o modo e o intervalo de tempo para a análise histopatológica (3 e 7 dias). Os animais foram submetidos à aplicação de ultra-som contínuo e pulsado em dois segmentos venosos da orelha previamente determinados. Cada animal foi o seu próprio controle. Empregou-se a freqüência de 3MHz, intensidade de 3W/cm² nos ciclos pulsado e contínuo por 10 minutos, de forma estacionária. O grupo I foi submetido a eutanásia após 3 dias e o grupo II em 7 dias contemplando a fase aguda do processo inflamatório. Empregou-se o teste exato de Fisher e o teste de Mc Nemar para análise estatística. RESULTADOS: Obteve-se trombose venosa e aumento de linfócitos de forma significativa (p= 0,032) nos grupos tratados com o modo contínuo. O modo pulsado não provocou efeitos deletérios. Outros achados foram congestão, edema, hemorragia e lesão da parede vascular. CONCLUSÕES: O ultra-som pulsado não provoca qualquer alteração na parede vascular nas condições do experimento.O ultra-som contínuo induz a trombose venosa e aumento dos linfócitos de forma significativa.PURPOSE: The purpose of this experimental work was evaluate the effects of low intensity in the auricular vein of rabbits. METHODS: Twenty rabbits were divided in two groups of ten animals. The groups differed about the place where the continuous and pulsed ultrasound were applied and the period that the material was collected for the morphologic examination (3 and 7 days). Acoustic coupling gel was used on marginal ear vein, each animal underwent continuous and pulsed ultrasound treatment, in segments previously marked with indelible ink. Each animal provided its own control. Ultrasound was used in the frequency of 3MHz, intensity of 3W/cm² in the pulsed and continuous modes during 10min in a stationary way. The group I was euthanized after 3 days and the group II after 7 days contemplating the acute phase of the inflammatory process. We applied the Fisher and Mc Nemar's tests for statistical analysis. RESULTS: Venous thrombosis and lymphocytes increment occurred significantly (p= 0,032) due continuous mode ultrasound. Other minor findings were congestion, edema, rupture of vessel wall and hemorrhage. CONCLUSIONS: continuous ultrasound causes venous thrombosis and lymphocytes increment. |
Databáze: | Directory of Open Access Journals |
Externí odkaz: |